HPS14-240L air-water heat pump with tank, 14kW

14.5 kW for heating and 13.5 kW for cooling

VIVAX air-water heat pump split systems are for heating and cooling heating water and heating domestic water.

Additional information >>

SKU: HPS14-240l Category:

Description

Set HPS14 – 14.5 kW for heating and 13.5 kW for cooling

VIVAX heat pump outdoor part HPS-48CH140AERI/O3s R32 rated power is 14.5 kW for heating and 13.5 kW for cooling.

Nominal heating capacity A7/W35 (kW) 14.5
COP coefficient 4.7
Nominal cooling capacity A35/W18 (kW) 13.5
EER coefficient 3.6
Compressor – Type Double rotor
External Fan – Motor Type DC fan
Number of fans 1
Heat exchanger – type Fin-coil
Refrigerant R32
Amount of refrigerant (kg) 1.84
Sound power level (dB(A)) 65
Device dimensions (mm) 1118x865x523
Package dimensions (mm) 1180 x 890 x 560
Net/gross weight (kg) 112/125
Refrigerant pipe diameter (mm) – Liquid 9.52
Refrigerant pipe diameter (mm) – Gas 15.88
Pipe connection method With nut, without welding
Maximum height difference (m) 20
Maximum pipe length (m) 2-30
Refrigerant replenishment (g/m) 38
Power source 380-415 V / 3 Ph / 50 Hz

The VIVAX heat pump HPS-120HM155AERI/IT241H3s is a hydro box with an additional 3 kW heater located in your room.

Heat pumps are a unique solution for household heating, cooling and domestic hot water. Their working principle is to extract heat from the surrounding air and transfer this heat through coolant pipes to water and household heating in a closed space. The hydraulic box heats the water using the coolant from the outdoor unit with a PTV, 240 liter tank. The heated water circulates through parts of the heating system, such as underfloor heating, fan coils, radiators, as well as the internal coil of the domestic hot water tank. The hot water of the distributed unit circulates around the domestic hot water coil in the tank. Immersion heaters are often installed in hot water tanks as a backup.

Rated power (kW) 15.5
Hot water tank – type Stainless steel
Hot water tank – material SUS 316L
Hot water tank – water volume (L) 240
Hot water tank – maximum water pressure limit (bar) 10
Hot water tank – insulation material Polyurethane (cyclopentane)
Hot water tank – insulation thickness 45
Expansion tank (primary circuit) – volume (L) 8
Additional electric heater – fitted as standard (kW) 3
Total volume of water (L) 5
Room temperature range (˚C) 5 °C ≤ T ≤ 35 °C
Water outlet temperature – cooling (˚C) 5 °C ≤ T ≤ 25 °C
Water supply temperature – heating (˚C) 25 °C ≤ T ≤ 65 °C
Water pump – delivery height (m) 9
Water connection diameter (mm) – heating/cooling R 1″
Water connection diameter (mm) – PTV R 3/4″
Refrigerant pipe diameter – liquid (mm) 9.52
Refrigerant pipe diameter – gas (mm) 15.88
Safety valve (Mpa) 0.3
Minimum water consumption (m³/h) 0.6
Heat exchanger – type Plate heat exchanger
Sound power level (dB(A)) 44
Device dimensions (mm) 600 x 1943 x 600
Package dimensions (mm) 730 x 2180 x 730
Net/gross weight (kg) 159/180
Power source 220-240 V / 1 Ph / 50 Hz
Application Heating + cooling + domestic hot water
Type Split (external unit + hydraulic box)
Refrigerant piping Between the outdoor unit and the hydraulic box
Water pipe Between hydrobox and indoor heating devices
Installation Underfloor heating circuits
Fan coil units
Low temperature radiators
Domestic hot water tank
Additional heat sources (e.g. boilers and boilers)

SPLIT TYPE OUTDOOR PART
The outdoor part absorbs heat from the outside air and transfers it to the interior through the refrigerant piping.
HYDROBOX
The hydrobox heats water with refrigerant from the external unit. The heated water circulates through heating devices such as underfloor heating, radiators, fan coils, as well as the internal coil of the domestic hot water tank.
DOMESTIC WATER TANK
Warm water from the hydro box is circulated through the heating water coil of the domestic hot water tank, heating the domestic hot water inside the tank. As a backup option, electric heaters could be installed in the domestic hot water tanks.
USER INTERFACE
The user interface is connected to the split device via a signal cable. Its main functions are ON/OFF, parameter setting, timer and service parameter setting.

DIAGRAM OF THE SPLIT SYSTEM